Florida Gas Transmission v. TRAN
── Florida Gas Transmission v. TRAN ──
Court: Court of Appeals for the Fifth Circuit
Date: May 20, 2026
Category: Agency
Case: 24-60420 Document: 83-1 Page: 1 Date Filed: 05/20/2026
United States Court of Appeals
for the Fifth Circuit
United States Court of Appeals
Fifth Circuit
FILED
____________
May 20, 2026
No. 24-60420 Lyle W. Cayce
____________ Clerk
Florida Gas Transmission Company, L.L.C., a subsidiary
of Energy Transfer, L.P.,
Petitioner,
versus
United States Department of Transportation; Pipeline
and Hazardous Materials Safety Administration;
Office of Pipeline Safety,
Respondents.
______________________________
Petition for Review of an Order of the
Department of Transportation, National Transportation Safety Board
Agency No. 4-2022-032-NOPV
______________________________
Before Haynes, Ho, and Oldham, Circuit Judges.
Per Curiam: *
A natural gas pipeline burst. The Pipeline and Hazardous Materials
Safety Administration, an agency within the U.S. Department of
Transportation, investigated the incident. It determined that the company
that owns and operates the pipeline violated two federal regulations, and
_____________________
*
This opinion is not designated for publication. See 5th Cir. R. 47.5.
Case: 24-60420 Document: 83-1 Page: 2 Date Filed: 05/20/2026
No. 24-60420
imposed fines accordingly. But we hold that the company complied with all
applicable regulations, and thus vacate the agency’s final order.
I.
Florida Gas Transmission Company is a natural gas transportation
company. Florida Gas operates the Sanford Lateral, a pipeline built in 1959
and previously operated by Enron. The line is made of low-frequency
electric-resistance-welded steel pipe. This type of pipe has seams which can
be vulnerable to corrosion and related seam-integrity issues.
Like most long-lived pipelines, the Sanford Lateral has experienced
ruptures, anomalies, and other incidents. It suffered ruptures in 2009 and
2012. But the cause of these ruptures is unknown. In 2014, Florida Gas
identified an anomaly on the line and, treating it as corrosion, installed a
sleeve to remediate the area. As part of its integrity-management program,
Florida Gas conducted in-line inspections in 2014 and 2019 using an axially
aligned magnetic-flux-leakage (MFL-A) tool. By contrast, a circumferential
magnetic-flux leakage (MFL-C) tool is better suited to detect certain seam
anomalies. See Florida Gas Transmission Company, Final Order, CPF No.
4-2022-032-NOPV, *12 (May 21, 2024) (“MFL-C [tools are] more sensitive
[than MFL-A tools] to axially aligned metal-loss defects.” (quotations
omitted)).
In 2020, the pipeline ruptured along its longitudinal seam. The
escaping gas ignited and burned roughly 51,500 square feet of land, causing
significant property damage but, fortunately, no injuries.
Subsequent inspection and failure analysis revealed the cause of the
rupture as stress-corrosion cracking, a type of corrosion which forms on the
outside of the pipeline and does not involve significant metal loss. Stress-
corrosion cracking is challenging to spot because, “[u]nlike a component
widely known to have manufacturing defects that can be identified by an